With different electrical termination styles, clamping mechanisms and the ability to accommodate holes and cutouts, mica-insulated band heaters are used successfully in many applications, particularly plastics.
 

Loss Prevention for Band Heaters

Most band heaters with heating plate do not “burn out”; instead, environmental factors create a short, cause hot spots to develop, or simply push the heater beyond its normal operating temperature. All of these factors cause a heater to fail prematurely and require replacement. Obviously, minimizing these environmental factors can reduce the frequency of replacing band heaters in your operation.

Contamination.By far, the most frequent culprit of band heater failure is contamination. Liquid plastic, hydraulic oil and moisture (often from high ambient humidity) are three main causes of premature failure from contamination. Obviously, keeping the heaters free of contaminants will reduce failure and replacement rates. In applications where liquid plastic and oil exposure are frequent and difficult to manage, the best solution may be to select a low cost band -- the heater will be replaced often, but the financial loss will be minimized. Alternatively, a band heater designed to resist contamination can be used. Keep in mind, though, that most heaters fail from lead wire damage caused by contamination -- not from contaminants finding their way inside the band -- and contaminant-resistant heaters will not prevent lead wire damage.

Poor Contact Between Heater and Barrel.The second most common cause of premature failure is poor contact between the machine barrel and the band heater. A tight fit is critical. Without it, localized hot spots can form on the band and cause the resistance wire to fail.

 

AB Hukuku ve Avrupa Birliği Hukuku kategorisinde (120 puan) sordu | 171

Bu soruya cevap vermek için lütfen giriş yapınız veya kayıt olunuz.

7,521 soru
5,160 cevap
737 yorum
2,058,939 üye